Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
J Cardiovasc Dev Dis ; 10(5)2023 May 14.
Article in English | MEDLINE | ID: covidwho-20240269

ABSTRACT

Remote monitoring (RM) is the newest function of cardiac implantable electronic devices (CIEDs). In our observational retrospective analysis, we aimed to assess whether telecardiology could be a safe alternative to routine outpatient examinations during the COVID-19 pandemic. The in- and outpatient visits, the number of acute cardiac decompensation episodes, the RM data from CIEDs, and general condition were examined via questionnaires (KCCQ, EQ-5D-5L). Regarding the enrolled 85 patients, the number of personal patient appearances was significantly lower in the year following the pandemic outbreak compared to the previous year (1.4 ± 1.4 and 1.9 ± 1.2, p = 0.0077). The number of acute decompensation events was five before and seven during lockdown (p = 0.6). Based on the RM data, there was no significant difference in heart failure (HF) markers (all related p > 0.05); only patient activity increased after restrictions were lifted compared to that before the lockdown (p = 0.03). During restrictions, patients reported increased anxiety and depression compared to their previous state (p < 0.001). There was no subjective change in the perception of HF symptoms (p = 0.7). Based on the subjective perception and CIED data, the quality of life of patients with CIED did not deteriorate during the pandemic, but their anxiety and depression intensified. Telecardiology may be a safe alternative to routine inpatient examination.

2.
Pharmacy (Basel) ; 11(2)2023 Mar 03.
Article in English | MEDLINE | ID: covidwho-2303232

ABSTRACT

For patients with cardiac implantable electronic devices (CIEDs), arrythmias such as atrial fibrillation (AF) can be detected and actions taken to rapidly assess and initiate treatment where appropriate. Actions include timely initiation of anticoagulation, review of blood pressure, and optimization of cholesterol/lipids to prevent unfavorable outcomes, such as stroke and other cardiovascular complications. Delays to initiating anticoagulation can have devastating consequences. We sought to implement a virtual clinic, where a pharmacist reviews patient referrals from a CIED clinic after detecting AF from the CIED. Anticoagulation choice is determined by patient-specific factors, and a shared patient-provider decision to start oral anticoagulation is made. In addition, blood pressure readings and medications are assessed with lipid-lowering therapies for optimization. A total of 315 patients have been admitted through this clinic and anticoagulated over a two-year span; in addition, 322 successful interventions were made for optimization of cardiac therapy. Rapid initiation of anticoagulation within five days of referral was likely to have reduced unfavorable outcomes, such as stroke and other cardiovascular optimizations, leading to improved patient outcomes.

3.
J Am Heart Assoc ; 12(3): e027500, 2023 02 07.
Article in English | MEDLINE | ID: covidwho-2214214

ABSTRACT

Background Remote monitoring (RM) of cardiac implantable electronic devices has been shown to improve cardiovascular morbidity and mortality. To date, no studies have investigated disparities in use and delivery of RM. This study was performed to investigate if racial and socioeconomic disparities are present in cardiac implantable electronic device RM. Methods and Results This was a retrospective observational cohort study at a single tertiary care center in the United States. Patients who received a newly implanted cardiac implantable electronic device or device upgrade between January 2017 and December 2020 were included. Patients were classified as RM positive (RM+) when they underwent at least ≥2 remote interrogations per year during follow-up. Of all eligible patients, 2520 patients were included, and 34% were women. The mean follow-up was 25 months. Mean age was 71±14 years. Pacemakers constituted 66% of implanted devices, whereas 26% were implantable cardioverter-defibrillators, and 8% were cardiac resynchronization therapy with implantable cardioverter-defibrillators. Most patients (83%) were of European American ancestry. During follow-up, 66% of patients were classified as RM+. Patients who were younger, European American, college-educated, lived in a county with higher median household income, and were active on the hospital's patient portals were more frequently RM+. In an adjusted regression model, RM+ remained associated with the use of the online patient portal (odds ratio [OR], 2.889 [95% CI, 2.387-3.497]), presence of an implantable cardioverter-defibrillator (OR, 1.489 [95% CI, 1.207-1.835]), advanced college degree (OR, 1.244 [95% CI, 1.014-1.527]), and lastly with European American ancestry (P<0.05). During the years of the COVID-19 pandemic, the number of RM+ patients increased, whereas the association with ancestry and ethnicity decreased. Conclusions Despite being offered to all patients at implantation, significant disparities were present in cardiovascular implantable electronic device RM in this cohort. Disparities were partly reversed during COVID-19. Further studies are needed to examine health center- and patient-specific factors to overcome these barriers, and to facilitate equal opportunities to participate in RM.


Subject(s)
COVID-19 , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Cohort Studies , Follow-Up Studies , Pandemics , Remote Sensing Technology/methods , COVID-19/epidemiology , Cardiac Resynchronization Therapy/methods
4.
Front Cardiovasc Med ; 9: 1010409, 2022.
Article in English | MEDLINE | ID: covidwho-2099117

ABSTRACT

Minimizing the number of personnel in the cardiac catheterization laboratory (CCL) and the times of CCL door openings contribute to reduce the infection risk of medical staff and patients, particularly during the COVID-19 pandemic. The usage of 5G-CTP system enables device specialists to conduct remote parameter testing and programming without entering the CCL, potentially reducing the exposure risk of medical staff and patients to COVID-19 infection.

5.
Cardiol J ; 29(1): 27-32, 2022.
Article in English | MEDLINE | ID: covidwho-1593294

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) pandemic disorganised healthcare systems and has caused a reduction in the number of hospitalizations and procedures. Cardiac implantable electronic device (CIED) procedure rates and clinical characteristics of their recipients were compared in corresponding weeks of 2019 and 2020 were analyzed. METHODS: The database of the National Health Fund (NHF) in Poland was retrospectively analyzed. 3206 patients who underwent CIED implantation in the Silesia - a region in Southern Poland comprising an adult population of 3.8 million between 12th and 31st week of 2020. Patients were classified into groups: the recipient of an implantable cardioverter-defibrillator or cardiac resynchronization therapy group (ICD/CRT) or pacemaker group (PM). RESULTS: During the pandemic a reduction of 39.38% of implantations was observed compared to the same period in 2019 (1210 vs. 1996 patients) and had impacted both groups. Two phases lasting 10 weeks each could be distinguished: total lockdown (maximal reduction) and the recovery phase with growing numbers of procedures. Patient baseline characteristics (sex, age, comorbidities) who were implanted during the COVID-19 pandemic did not differ from the 2019 period. The rate of peri-procedural mortality was also similar. CONCLUSIONS: During COVID-19 pandemic period a reduction in CIED implantations of all types was observed. Despite the decreased number of performed CIED implants, no differences in baseline patient characteristics were observed.


Subject(s)
COVID-19 , Defibrillators, Implantable , Adult , COVID-19/epidemiology , Communicable Disease Control , Electronics , Humans , Pandemics , Poland , Retrospective Studies , SARS-CoV-2
6.
J Arrhythm ; 37(6): 1522-1531, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1437059

ABSTRACT

BACKGROUND: Transvenous lead extraction (TLE) for implantable cardiac-devices is traditionally performed under general anesthesia (GA). This can lead to greater risk of exposure to COVID-19, longer recovery-times and increased procedural-costs. We report the feasibility/safety of TLE using conscious-sedation alone with immediate GA/cardiac-surgery back-up if needed. METHODS: Retrospective case-series of consecutive TLEs performed using conscious-sedation alone between March 2016 and December 2019. All were performed in the electrophysiology-laboratory using intravenous Fentanyl, Midazolam/Diazepam with a stepwise approach using locking-stylets/cutting-sheaths, including mechanical-sheaths. Baseline patient-characteristics, procedural-details and TLE outcomes (including procedure-related complications/death) were recorded. RESULTS: A total of 130 leads were targeted in 54 patients, mean age ± SD 74.6 ± 11.8years, 47(87%) males; dual-chamber pacemakers (n = 26; 48%), cardiac resynchronization therapy-defibrillators (n = 17; 31%) and defibrillators (n = 8; 15%) were commonest extracted devices. Mean ± SD/median (range) lead-dwell times were 11.0 ± 8.8/8.3 (0.3-37) years, respectively. Extraction indications included systemic infection (n = 23; 43%) and lead/pulse-generator erosion (n = 27; 50%); mean 2.1 ± 2.0 leads were removed per procedure/mean procedure-time was 100 ± 54 min. Local anesthetic (LA) was used for all (mean-dose: 33 ± 8 ml 1% lidocaine), IV drug-doses used (mean ± SD) were: midazolam: 3.95 ± 2.44 mg, diazepam: 4.69 ± 0.89 mg and fentanyl: 57 ± 40 µg. Complete lead-extraction was achieved in 110 (85%) leads, partial lead-extraction (<4 cm-fragment remaining) in 5 (4%) leads. Sedation-related hypotension requiring IV fluids occurred in 2 (managed without adverse-consequences) and hypoxia requiring additional airway-management in none. No procedural deaths occurred, one patient required emergency cardiac surgery for localized ventricular perforation, nine had minor complications (transient hypotension/bradycardia/pericardial effusion not requiring intervention). CONCLUSION: TLE undertaken using LA/conscious-sedation was safe/feasible in our series and associated with good clinical outcome/low procedural complications. Reduced risk of aerosolization of COVID-19 and quicker patient recovery/reduced anesthetic risk are potential benefits that warrant further study.

7.
J Clin Med ; 10(18)2021 Sep 10.
Article in English | MEDLINE | ID: covidwho-1409875

ABSTRACT

The COVID-19 pandemic has had a profound impact on the organisation of health care in Italy, with an acceleration in the development of telemedicine. To assess the impact of the COVID-19 pandemic on the spread of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) in Italy, a survey addressed to cardiologists operating in all Italian CIED-implanting centres was launched. A total of 127 cardiologists from 116 Italian arrhythmia centres took part in the survey, 41.0% of all 283 CIED-implanting centres operating in Italy in 2019. All participating centres declared to use RM of CIEDs. COVID-19 pandemic resulted in an increase in the use of RM in 83 (71.6%) participating centres. In a temporal perspective, an increase in the median number of patients per centre followed up by RM was found from 2012 to 2017, followed by an exponential increase from 2017 to 2020. In 36 participating centres (31.0%) a telehealth visits service was activated as a replacement for in-person outpatient visits (in patients with or without CIED) during the COVID-19 pandemic. COVID-19 pandemic has caused an acceleration in the use of RM of CIEDs and in the use of telemedicine in the clinical practice of cardiology.

8.
Arch Cardiol Mex ; 91(Suplemento COVID): 034-039, 2021 Dec 20.
Article in English | MEDLINE | ID: covidwho-1372194

ABSTRACT

INTRODUCTION: The coronavirus disease (COVID-19) pandemic has generated serious repercussions on the health system, reducing the number of all cardiology procedures worldwide. OBJECTIVES: Describe the impact of the COVID-19 pandemic on the procedures performed by the electrophysiology department in a national referral center. METHODS: We made a retrospective review of our data base and we compared procedures made in the past 3 years since 2017-2019 with the procedures made in the 2020. We divided the procedures into two large groups: Cardiac Implantable Electronic Devices (CIED) related procedures and electrophysiological procedures (EP) which included conventional and complex ablations. RESULTS: There was a significant reduction in all the procedures, the average of procedures performed in the last 3 previous years was 467, while in 2020, we performed only 319 (p = 0.01); this represents a reduction of 33.4% in the total number of procedures. There was no statistical difference regarding the CIED related procedures, the average of procedures in the past 3 previous years was 174, and in 2020 we performed 190 procedures (p = 0.46). Regarding the EP, the average of the past 3 previous years was 293, while in 2020, we performed only 129 procedures (p < 0.01). The reduction in the EP was 55.97%. The most affected months were April, May, and June. CONCLUSIONS: The COVID-19 pandemic considerably affected the number of the procedures in our center, reducing it by 33.4%. The reduction of procedures fundamentally affected the ablations, with a reduction of 55.97%. The number of CIED related procedures was not affected.


Subject(s)
COVID-19 , Electrophysiologic Techniques, Cardiac/statistics & numerical data , Pandemics , Humans , Referral and Consultation , Retrospective Studies
9.
Europace ; 24(3): 473-480, 2022 03 02.
Article in English | MEDLINE | ID: covidwho-1364792

ABSTRACT

It is unclear to what extent the COVID-19 pandemic has influenced the use of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs). The present physician-based European Heart Rhythm Association (EHRA) survey aimed to assess the influence of the COVID-19 pandemic on RM of CIEDs among EHRA members and how it changed the current practice. The survey comprised 27 questions focusing on RM use before and during the pandemic. Questions focused on the impact of COVID-19 on the frequency of in-office visits, data filtering, reasons for initiating in-person visits, underutilization of RM during COVID-19, and RM reimbursement. A total of 160 participants from 28 countries completed the survey. Compared to the pre-pandemic period, there was a significant increase in the use of RM in patients with pacemakers (PMs) and implantable loop recorders (ILRs) during the COVID-19 pandemic (PM 24.2 vs. 39.9%, P = 0.002; ILRs 61.5 vs. 73.5%, P = 0.028), while there was a trend towards higher utilization of RM for cardiac resynchronization therapy-pacemaker (CRT-P) devices during the pandemic (44.5 vs. 55%, P = 0.063). The use of RM with implantable cardioverter-defibrillators (ICDs) and CRT-defibrillator (CRT-D) did not significantly change during the pandemic (ICD 65.2 vs. 69.6%, P = 0.408; CRT-D 65.2 vs. 68.8%, P = 0.513). The frequency of in-office visits was significantly lower during the pandemic (P < 0.001). Nearly two-thirds of participants (57 out of 87 respondents), established new RM connections for CIEDs implanted before the pandemic with 33.3% (n = 29) delivering RM transmitters to the patient's home address, and the remaining 32.1% (n = 28) activating RM connections during an in-office visit. The results of this survey suggest that the crisis caused by COVID-19 has led to a significant increase in the use of RM of CIEDs.


Subject(s)
COVID-19 , Defibrillators, Implantable , Physicians , COVID-19/epidemiology , Humans , Pandemics , SARS-CoV-2 , Surveys and Questionnaires
10.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Article in English | MEDLINE | ID: covidwho-383246

ABSTRACT

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Subject(s)
Betacoronavirus , Coronavirus Infections , Defibrillators, Implantable , Electrophysiologic Techniques, Cardiac , Pandemics , Pneumonia, Viral , Australia/epidemiology , COVID-19 , Coronavirus Infections/epidemiology , Coronavirus Infections/physiopathology , Coronavirus Infections/therapy , Humans , Pneumonia, Viral/epidemiology , Pneumonia, Viral/physiopathology , Pneumonia, Viral/therapy , SARS-CoV-2
11.
J Interv Card Electrophysiol ; 58(3): 269-272, 2020 Sep.
Article in English | MEDLINE | ID: covidwho-378292

ABSTRACT

Coronavirus disease 2019 (COVID-19) is a major healthcare disaster in the modern times. Healthcare services must adapt to effectively juggle between pandemic management and maintenance of business-as-usual services so that both COVID-19 and non-COVID-19 patients receive appropriate clinical care. We share our experience of significant cardiac rhythm abnormalities seen in COVID-19 patients in Singapore, how the viral pandemic has affected the cardiac electrophysiology and pacing service in a large acute care general hospital and the steps taken to alleviate the negative impact.


Subject(s)
Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Cardiac Electrophysiology , Coronavirus Infections/complications , Coronavirus Infections/epidemiology , Pneumonia, Viral/complications , Pneumonia, Viral/epidemiology , Arrhythmias, Cardiac/epidemiology , Betacoronavirus , COVID-19 , Hospitals, General/organization & administration , Humans , Infection Control/organization & administration , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pandemics , SARS-CoV-2 , Singapore/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL